Administrator Guide

Apr 10 19:19:18: %STKUNIT2-M:CP %FILEMGR-5-FILESAVED: Copied running-config
to startup-config in flash by default
Apr 10 19:19:18: %STKUNIT2-M:CP %CHMGR-5-RELOAD: User request to reload the
chassis
syncing disks... done
unmounting file systems...
unmounting /f10/flash (/dev/wd0e)...
unmounting /f10/ConfD/db (mfs:479)...
unmounting /usr/pkg (/dev/wd0i)...
unmounting /boot (/dev/wd0b)...
unmounting /usr (mfs:29)...
unmounting /force10 (mfs:24)...
unmounting /lib (mfs:21)...
unmounting /f10 (mfs:18)...
unmounting /tmp (mfs:9)...
unmounting /kern (kernfs)...
unmounting / (/dev/md0a)... done
rebooting...
Example (S4048–
ON)
Dell#conf t
Dell(conf)#mixed-mode-stacking enable
Dell#conf t
Dell(conf)#no mixed-mode-stacking enable
redundancy disable-auto-reboot
Prevent the S-Series stack management unit, stack member unit, and standby unit from rebooting if they fail.
Syntax
redundancy disable-auto-reboot stack-unit [1–6 | members]
To return to the default, use the no redundancy disable-auto-reboot stack-unit command.
Parameters
stack-unit Enter the stack-unit number. The range is from 1 to 6.
members Enter the keyword members for all stack-units.
Defaults Disabled (the failed switch is automatically rebooted).
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.10(0.0) Introduced on the S6100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.7.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
8.3.1.0 Added the members option.
Usage Information Enabling this command keeps the failed switch in the Failed state. The switch does not reboot until it is manually
rebooted. When enabled, it is not displayed in the running-config. When disabled, it is displayed in the running-
config.
1556 Stacking