Users Guide

peer-ovsdbserver-ip ovsdb-IP-address
The peer OVSDB server is the peer VLT device.
6 Enter the fail mode.
VxLAN INSTANCE mode
fail-mode secure
7 Enable the VxLAN instance.
VxLAN INSTANCE mode
no shutdown
NOTE: Dell EMC Networking recommends the non-secure fail mode if you are conguring VxLAN for a VLT setup and not to use
spanned VLAN IP address for peer OVSDB connectivity. Also using of controller connected IP address for peer OVSDB
connectivity leads to double failure, when connected link fails..
Conguring VLT for NSX-based VxLAN
After conguring NSX-based VxLAN on the device, congure VLT. To congure VLT for NSX-based VxLAN, follow these steps:
1 Enable VLT on a switch, then congure a VLT domain and enter VLT-domain conguration mode.
CONFIGURATION mode
vlt domain domain-id
The domain ID range is from 1 to 1000.
Congure the same domain ID on the peer switch
2 Congure the IP address of the management interface on the remote VLT peer to be used as the endpoint of the VLT backup link for
sending out-of-band hello messages.
VLT DOMAIN CONFIGURATION mode
back-up destination ip-address
3 Congure the port channel to be used as the VLT interconnect between VLT peers in the domain.
VLT DOMAIN CONFIGURATION mode
peer-link port-channel id-number
4 Assign VLT system MAC address.
VLT DOMAIN CONFIGURATION mode
system-mac mac-address mac-address
5 Enable peer routing.
VLT DOMAIN CONFIGURATION mode
peer-routing
6 Congure the primary priority.
VLT DOMAIN CONFIGURATION mode
primary-priority value
The priority values are from 1 to 65535. The default is 32768.
7 Congure the unit ID.
1142
Virtual Extensible LAN (VXLAN)