Service Manual

Table Of Contents
Version Description
9.0.2.0 Introduced on the S6000.
8.3.11.1 Introduced on the Z9000.
8.1.1.0 Introduced on the E-Series (IPv4).
7.8.1.0 Increased the name string to accept up to 140 characters. Prior
to 7.8.1.0, names were up to 16 characters long.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage Information
When all sequence numbers are exhausted, this feature permits re-assigning a new
sequence number to entries of an existing access-list.
seq
Assign a sequence number to a deny or permit filter in an extended IP access list while creating the filter.
Syntax
seq sequence-number {deny | permit} {ip-protocol-number | icmp |
ip | tcp | udp} {source mask | any | host ip-address} {destination
mask | any | host ip-address} [operator port [port]] [count [byte]
| log] [dscp value] [order] [monitor] [fragments] [no-drop]
Parameters
sequence-
number
Enter a number from 0 to 4294967290.
deny Enter the keyword deny to configure a filter to drop packets
meeting this condition.
permit Enter the keyword permit to configure a filter to forward
packets meeting this criteria.
ip-protocol-
number
Enter a number from 0 to 255 to filter based on the protocol
identified in the IP protocol header.
icmp Enter the keyword icmp to configure an ICMP access list filter.
ip Enter the keyword ip to configure a generic IP access list. The
keyword ip specifies that the access list permits all IP protocols.
tcp Enter the keyword tcp to configure a TCP access list filter.
udp Enter the keyword udp to configure a UDP access list filter.
source Enter an IP address in dotted decimal format of the network
from which the packet was received.
Access Control Lists (ACL) 277