Service Manual

Table Of Contents
NOTE: For v1 / v2c trap configuration, if the community-string is not defined
using the snmp-server community command prior to using this command,
the default form of the snmp-server community command automatically is
configured with the community-name the same as specified in the
snmp-
server host command.
Configuring Informs
To send an inform, use the following steps:
1 Configure a remote engine ID.
2 Configure a remote user.
3 Configure a group for this user with access rights.
4 Enable traps.
5 Configure a host to receive informs.
Related
Commands
snmp-server enable traps — enables SNMP traps.
snmp-server community — configures a new community SNMPv1 or SNMPv2c.
snmp-server location
Configure the location of the SNMP server.
Syntax
snmp-server location text
To delete the SNMP location, use the no snmp-server location command.
Parameters
text Enter an alpha-numeric text string, up to 55 characters long.
Defaults Not configured.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see
the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.10(0.0) Introduced on the S6100–ON.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
Simple Network Management Protocol (SNMP) and Syslog 1843