To return to the default, use the no sflow polling-interval interval
command.
Parameters
interval value Enter the interval value in seconds. The range is from 15 to
86400 seconds. The default is 20 seconds.
Defaults 20 seconds
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see
the relevant Dell Networking OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100-ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage Information The polling interval for an interface is the maximum number of seconds between
successive samples of counters sent to the collector. This command changes the
global default counter polling (20 seconds) interval. You can configure an interface to
use a different polling interval.
Related
Commands
sflow polling-interval (Interface) — sets the polling interval for an interface.