Service Manual

Table Of Contents
Version Description
7.8.1.0 The Boot Flash field displays the code level for boot code 2.8.1.1
and newer, while older boot codes display as "Present".
7.7.1.0 Added Master Priority field.
7.6.1.0 Introduced on the S-Series.
Example (show
system brief)
Dell# show system brief
Stack MAC : 34:17:eb:f2:90:c4
Reload-Type : normal-reload [Next boot : normal-reload]
-- Stack Info --
Unit UnitType Status ReqTyp CurTyp Version Ports
------------------------------------------------------------------------------
1 Member not present
2 Management online S4048-ON S4048-ON 1-0(0-4160) 72
3 Member not present
4 Member not present
5 Member not present
6 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-----------------------------------------------------------
2 1 up AC up 7048
2 2 down UNKNOWN down 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
----------------------------------------------------
2 1 up up 7021 up 6971
2 2 up up 7021 up 7072
2 3 up up 6971 up 7021
Speed in RPM
Example (S4048–
ON)
Dell# show system
Stack MAC : 34:17:eb:f2:90:c4
Reload-Type : normal-reload [Next boot : normal-reload]
-- Unit 2 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S4048-ON - 54-port TE/FG (SK-ON)
Current Type : S4048-ON - 54-port TE/FG (SK-ON)
Master priority : 0
Hardware Rev : 2.0
Num Ports : 72
Up Time : 5 hr, 30 min
Dell Networking OS Version : 1-0(0-4160)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Burned In MAC : 34:17:eb:f2:90:c4
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
----------------------------------------------------
2 1 up AC up 7048
2 2 down UNKNOWN down 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
----------------------------------------------------
2 1 up up 7072 up 7072
2 2 up up 7021 up 6922
2 3 up up 7021 up 7021
Control and Monitoring 174