Service Manual
iSCSI Optimization
Internet small computer system interface (iSCSI) optimization enables quality-of-service (QoS) treatment for iSCSI storage trac on an
S4048–ON system.
To congure and verify the iSCSI optimization feature, use the following Dell Networking OS commands.
Topics:
• advertise dcbx-app-tlv
• iscsi aging time
• iscsi cos
• iscsi enable
• iscsi priority-bits
• iscsi prole-compellant
• iscsi target port
• show iscsi
• show iscsi session
• show iscsi session detailed
• show run iscsi
advertise dcbx-app-tlv
Congure DCBX to send iSCSI TLV advertisements.
Syntax
advertise dcbx-app-tlv iscsi
To disable DCBX iSCSI TLV advertisements, use the no advertise dcbx-app-tlv iscsi command.
Defaults Disabled.
Command Modes PROTOCOL LLDP
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.12.0 Introduced on the S4810.
8.3.16.0 Introduced on MXL 10/40GbE Switch IO Module.
Usage Information You can congure iSCSI TLVs to send either globally or on a specied interface. The interface conguration takes
priority over global conguration.
28
iSCSI Optimization 867