Administrator Guide
telnet
Connect through Telnet to a server. The Telnet client and server in Dell EMC Networking support IPv4 and IPv6 connections.
You can establish a Telnet session directly to the router or a connection can be initiated from the router.
NOTE: The Telnet server and client are VRF-aware. Using the vrf parameter in this command, you can make a Telnet
server or client to listen to a specific VRF. This capability enables a Telent server or client to look up the correct routing
table and establish a connection.
Syntax
telnet {host | ip-address | ipv6-address prefix-length | vrf vrf instance
name} [/source-interface]
Parameters
host Enter the name of a server.
ip-address
Enter the IPv4 address in dotted decimal format of the server.
ipv6-address
prefix-length
Enter the IPv6 address in the x:x:x:x::x format then the prefix length in the /x
format. The range is from /0 to /128.
NOTE: The :: notation specifies successive hexadecimal fields of zeros.
vrf instance
(Optional) Enter the keyword vrf then the VRF instance name.
source-interface (OPTIONAL) Enter the keywords /source-interface then the interface
information to include the source interface. Enter the following keywords and the
interface information:
● For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port/subport[/subport] information.
● For a 40-Gigabit Ethernet interface, enter the keyword fortyGigE then the
slot/port information.
● For a Loopback interface, enter the keyword loopback then a number from 0
to 16383.
● For a Null interface, enter the keyword null then the Null interface number.
● For a port channel interface, enter the keywords port-channel then a
number.
● For Tunnel interface types, enter the keyword tunnel then the slot/ port
information. The range is from 1 to 16383.
● For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
Defaults Not configured.
Command Modes
● EXEC
● EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
158 Control and Monitoring