Administrator Guide
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 up UNKNOWN up 10736
1 2 absent absent 0
2 1 up UNKNOWN up 10768
2 2 down UNKNOWN down 0
3 1 up UNKNOWN up 10672
3 2 absent absent 0
4 1 up UNKNOWN up 10685
4 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
------------------------------------------------------------------------------------
1 1 up up 10134 up 10031
1 2 up up 10031 up 9929
1 3 up up 10031 up 10031
2 1 up up 10031 up 10031
2 2 up up 10031 up 10031
2 3 up up 10031 up 10134
3 1 up up 10031 up 10134
3 2 up up 10031 up 10031
3 3 up up 10031 up 10031
4 1 up up 10031 up 10139
4 2 up up 10035 up 10033
4 3 up up 10031 up 10031
Speed in RPM
DellEMC#
The following example shows how to configure two new switches for stacking using 10G ports.
Dell-1(conf)#stack-unit 1 stack-group 0
Setting ports Te 1/1 Te 1/2 Te 1/3 Te 1/4 as stack group will make their interface configs
obsolete after
a reload.
[confirm yes/no]:yes
Dell-2(conf)#stack-unit 1 stack-group 0
Setting ports Te 1/1 Te 1/2 Te 1/3 as stack group will make their interface configs obsolete
after
a reload.
[confirm yes/no]:yes
Dell-1#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin Link Trunk
(Gb/s) Status Status Group
------------------------------------------------------------------
1/1 1/1 10 up up
1/2 1/2 10 up up
1/3 1/3 10 up up
1/4 1/4 10 up up
Add Units to an Existing Stack
You can add units to an existing stack in one of three ways.
• By manually assigning a new unconfigured unit a position in an existing stack.
• By adding a configured unit to an existing stack.
• By merging two stacks.
If you are adding units to an existing stack, you can either:
• allow Dell EMC Networking OS to automatically assign the new unit a position in the stack, or
• manually determine each units position in the stack by configuring each unit to correspond with the stack before connecting it.
• If you add a unit that has a stack number that conflicts with the stack, the stack assigns the first available stack number.
• If the stack has a provision for the stack-number that will be assigned to the new unit, the provision must match the unit type, or Dell
EMC Networking OS generates a type mismatch error.
874