Service Manual

-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
-----------------------------------------
1 1 up up 9360 up 9360
1 2 up up 9360 up 9360
2 1 up up 7680 up 7680
2 2 up up 7920 up 7680
3 1 up up 9360 up 9360
3 2 up up 9360 up 9360
4 1 up up 9120 up 9120
4 2 up up 9120 up 9360
Speed in RPM
The following example shows how to congure two new switches for stacking using 10G ports.
Dell-1(conf)#stack-unit 1 stack-group 1
Setting ports Gi 1/1 Gi 1/2 Gi 1/3 as stack group will make their interface configs
obsolete after
a reload.
[confirm yes/no]:yes
Dell-2(conf)#stack-unit 0 stack-group 0
Setting ports Gi 1/1 Gi 1/2 Gi 1/3 as stack group will make their interface configs
obsolete after
a reload.
[confirm yes/no]:yes
Dell-1#show system stack-ports
Topology: Ring
Interface Connection Link Speed Admin Link Trunk
(Gb/s) Status Status Group
------------------------------------------------------------------
1/1 1/1 10 up up
1/2 1/2 10 up up
1/3 1/3 10 up up
S4810-1#
Add Units to an Existing S-Series Stack
You can add units to an existing stack in one of three ways.
By manually assigning a new uncongured unit a position in an existing stack.
By adding a congured unit to an existing stack.
By merging two stacks.
If you are adding units to an existing stack, you can either:
allow Dell Networking OS to automatically assign the new unit a position in the stack, or
manually determine each units position in the stack by conguring each unit to correspond with the stack before connecting it.
If you add a unit that has a stack number that conicts with the stack, the stack assigns the rst available stack number.
If the stack has a provision for the stack-number that will be assigned to the new unit, the provision must match the unit type, or
Dell Networking OS generates a type mismatch error.
After the new unit loads, it synchronizes its running and startup congurations with the stack.
Manually Assigning a New Unit to an Existing Stack
To manually assign a new unit a position in an existing stack, use the following steps.
NOTE: For an S50 system, install the stacking modules in the new unit while the unit is not powered.
1. On the stack, determine the next available stack-unit number, and the management priority of the management unit.
EXEC Privilege mode
Stacking
735