Displaying Show sFlow on an Interface
To view sFlow information on a specic interface, use the following command.
Display sFlow conguration information and statistics on a specic interface.
EXEC mode
show sflow interface interface-name
Examples of the sFlow show Commands
The following example shows the show sflow interface command.
Dell#show sflow interface gigabitethernet 1/1
Gi 1/1
sFlow type :Ingress
Configured sampling rate :16384
Actual sampling rate :16384
Counter polling interval :20
Extended max header size :128
Samples rcvd from h/w :0
The following example shows the show running-config interface command.
Dell#show running-config interface gigabitethernet 1/16
!
interface GigabitEthernet 1/16
no ip address
mtu 9252
ip mtu 9234
switchport
sflow ingress-enable
sflow sample-rate 8192
no shutdown
Displaying Show sFlow on a Stack-unit
To view sFlow statistics on a specied stack-unit, use the following command.
Display sFlow conguration information and statistics on the specied interface.
EXEC mode
show sflow stack—unit slot-number
Example of Viewing sFlow Conguration (Line Card)
Dell#show sflow stack-unit 1
stack-unit 1
Samples rcvd from h/w :165
Samples dropped for sub-sampling :69
Total UDP packets exported :77
UDP packets exported via RPM :77
UDP packets dropped :
Conguring Specify Collectors
The sflow collector command allows identication of sFlow collectors to which sFlow datagrams are forwarded.
You can specify up to two sFlow collectors. If you specify two collectors, the samples are sent to both.
Identify sFlow collectors to which sFlow datagrams are forwarded.
CONFIGURATION mode