Service Manual
0 Gi 1/1 Gi 1/2 rx Port N/A N/A
Dell(conf)#monitor session 0
Dell(conf-mon-sess-0)#source po 10 dest ten 1/2 dir rx
Dell(conf-mon-sess-0)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ----------- --- ---- --------- --------
0 Gi 1/1 Gi 1/2 rx Port N/A N/A
0 Po 10 Gi 1/2 rx Port N/A N/A
Dell(conf)#monitor session 1
Dell(conf-mon-sess-1)#source vl 40 dest ten 1/3 dir rx
Dell(conf-mon-sess-1)#flow-based enable
Dell(conf-mon-sess-1)#exit
Dell(conf)#do show monitor session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ----------- --- ---- --------- --------
0 Gi 1/1 Gi 1/2 rx Port N/A N/A
0 Po 10 Gi 1/2 rx Port N/A N/A
1 Vl 40 Gi 1/3 rx Flow N/A N/A
Note: Source as VLAN is achieved via Flow based mirroring. Please refer section Enabling Flow-Based Monitoring.
In the following example, the host and server are exchanging trac which passes through the uplink interface 1/1. Port 1/1 is the
monitored port and port 1/42 is the destination port, which is congured to only monitor trac received on gigabitethernet 1/1
(host-originated trac).
Figure 93. Port Monitoring Example
Conguring Monitor Multicast Queue
To congure monitor QoS multicast queue ID, use the following commands.
1. Congure monitor QoS multicast queue ID.
CONFIGURATION mode
Port Monitoring
555