Service Manual
Conguring a Switch for NLB
To enable a switch for Unicast NLB mode, perform the following steps:
Enter the ip vlan-flooding command to specify that all Layer 3 unicast routed data trac going through a VLAN member
port oods across all the member ports of that VLAN.
CONFIGURATION mode
ip vlan-flooding
There might be some ARP table entries that are resolved through ARP packets, which had the Ethernet MAC SA dierent from
the MAC information inside the ARP packet. This unicast data trac ooding occurs only for those packets that use these ARP
entries.
To enable a switch for Multicast NLB mode, perform the following steps:
1. Add a static ARP entry by entering the arp ip-address multicast-mac-address command in Global conguration
mode to associate an IP address with a multicast MAC address in the switch.
INTERFACE mode
arp ip-address multicast-mac-address interface
This setting causes the multicast MAC address to be mapped to the cluster IP address for the NLB mode of operation of the
switch.
2. Associate specic MAC or hardware addresses to VLANs.
CONFIGURATION mode
mac-address-table static multicast-mac-address vlan vlan-id output-range interface
442