Service Manual
Table 32. Network Policy Applications
Type Application Description
0 Reserved —
1 Voice Specify this application type for dedicated IP telephony
handsets and other appliances supporting interactive voice
services.
2 Voice Signaling Specify this application type only if voice control packets use
a separate network policy than voice data.
3 Guest Voice Specify this application type for a separate limited voice
service for guest users with their own IP telephony handsets
and other appliances supporting interactive voice services.
4 Guest Voice Signaling Specify this application type only if guest voice control
packets use a separate network policy than voice data.
5 Softphone Voice Specify this application type only if guest voice control
packets use a separate network policy than voice data.
6 Video Conferencing Specify this application type for dedicated video conferencing
and other similar appliances supporting real-time interactive
video.
7 Streaming Video Specify this application type for dedicated video conferencing
and other similar appliances supporting real-time interactive
video.
8 Video Signaling Specify this application type only if video control packets use
a separate network policy than video data.
9–255 Reserved —
Figure 68. LLDP-MED Policies TLV
Extended Power via MDI TLV
The extended power via MDI TLV enables advanced PoE management between LLDP-MED endpoints and network connectivity
devices.
Advertise the extended power via MDI on all ports that are connected to an 802.3af powered, LLDP-MED endpoint device.
• Power Type — there are two possible power types: power source entity (PSE) or power device (PD). The Dell Networking
system is a PSE, which corresponds to a value of 0, based on the TIA-1057 specication.
• Power Source — there are two possible power sources: primary and backup. The Dell Networking system is a primary power
source, which corresponds to a value of 1, based on the TIA-1057 specication.
• Power Priority — there are three possible priorities: Low, High, and Critical. On Dell Networking systems, the default power
priority is High, which corresponds to a value of 2 based on the TIA-1057 specication. You can congure a dierent power
priority through the CLI. Dell Networking also honors the power priority value the powered device sends; however, the CLI
conguration takes precedence.
• Power Value — Dell Networking advertises the maximum amount of power that can be supplied on the port. By default the
power is 15.4W, which corresponds to a power value of 130, based on the TIA-1057 specication. You can advertise a dierent
power value using the max-milliwatts option with the power inline auto | static command. Dell Networking also
honors the power value (power requirement) the powered device sends when the port is congured for power inline
auto
.
Link Layer Discovery Protocol (LLDP)
427