Service Manual
Trac type /
Application type
Switch initiated trac Switch-destined trac Transit Trac
management port is down or route lookup
fails, packets are dropped
Non-EIS
management
application
Front-end default route will take
higher precedence over
management default route and
SSH session to an unknown
destination uses the front-end
default route only. No change in
the existing behavior.
If source TCP/UDP port matches a
management application and the source IP
address is a management port IP address, the
management port is the preferred egress port
selected based on route lookup in EIS table. If
the management port is down or the route
lookup fails, packets are dropped
Trac from
management port to
data port and from data
port to management
port is blocked
• EIS is enabled implies that EIS feature is enabled and the application might or might not be congured as a management
application
• EIS is disabled implies that either EIS feature itself is disabled or that the application is not congured as a management
application
Transit Trac
This phenomenon occurs where trac is transiting the switch. Trac has not originated from the switch and is not terminating on
the switch.
• Drop the packets that are received on the front-end data port with destination on the management port.
• Drop the packets that received on the management port with destination as the front-end data port.
Switch-Destined Trac
This phenomenon occurs where trac is terminated on the switch. Trac has not originated from the switch and is not transiting
the switch.
The switch accepts all trac destined to the switch, which is received on management or front-end data port. Response trac with
management port IP address as source IP address is handled in the same manner as switch originated trac.
Switch-Originated Trac
This phenomenon occurs where trac is originating from the switch.
1. Management Applications (Applications that are congured as management applications):
The management port is an egress port for management applications. If the management port is down or the destination is not
reachable through the management port (next hop ARP is not resolved, and so on), and if the destination is reachable through
a data port, then the management application trac is sent out through the front-end data port. This fallback mechanism is
required.
2. Non-Management Applications (Applications that are not congured as management applications as dened by this feature):
Non-management application trac exits out of either front-end data port or management port based on routing table. If there
is a default route on both the management and front-end data port, the default for the data port is preferred route.
Behavior of Various Applications for Switch-Initiated Trac
This section describes the dierent system behaviors that occur when trac is originating from the switch:
EIS Behavior: If the destination TCP/UDP port matches a congured management application, a route lookup is done in the EIS
table and the management port gets selected as the egress port. If management port is down or the route lookup fails, packets are
dropped.
298
Internet Group Management Protocol (IGMP)