Administrator Guide
Version Description
7.7.1.0 Added Master Priority field.
7.6.1.0 Introduced on the S-Series.
Example (show
system brief)
Example (3048–
ON)
Dell>show system stack-unit 5
-- Unit 5 --
Unit Type : Management Unit
Status : online
Next Boot : online
Required Type : S3048-ON - 52-port GE/TE (SG-ON)
Current Type : S3048-ON - 52-port GE/TE (SG-ON)
Master priority : 0
Hardware Rev : 0.0
Num Ports : 52
Up Time : 2 day, 22 hr, 25 min
Dell EMC Networking OS Version : 9-13(0-0)
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : 3.24.2.6
Boot Selector : 3.24.0.0-9
Memory Size : 2127638528 bytes
Temperature : 36C
Voltage : ok
Serial Number : NA
Part Number : 087651 Rev
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : CN-035GJR-77931-4BK-0003
PPID Revision : N/A
Service Tag : N/A
Expr Svc Code : 0
Auto Reboot : enabled
Burned In MAC : 74:e6:e2:f5:64:80
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed Power AvgPower AvgPowerStartTime
-------------------------------------------------------------------------------------
5 1 down UNKNOWN down 0 0 0 N/A
5 2 down AC absent 0 0 0 N/A
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed
------------------------------------------------------------------------------------
5 1 up up 0
5 2 up up 0
5 3 up up 0
Speed in RPM
show tech-support
Display a collection of data from other show commands, necessary for Dell EMC Networking technical support to perform
troubleshooting.
Syntax
show tech-support [stack-unit unit-id | page]
Parameters
stack-unit (OPTIONAL) Enter the keywords stack-unit to view CPU memory usage for the
stack member designated by unit-id.
Control and Monitoring 141