Users Guide
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.11(2.0P1) Introduced on the C9010, S3048–ON, S6100–ON and Z9100–ON.
Usage Information Enables Intel CPU LPC (Low Pin Count) clock-failure monitoring and issues a warning syslog to the user to take
appropriate action if signal degradation is seen.
enable optic-info-update interval
Enable polling intervals of optical information updates for simple network management protocol (SNMP).
Syntax
enable optic-info-update [interval seconds]
To disable optical power information updates, use the no enable optic-info-update interval
command.
Parameters
interval seconds Enter the keyword interval then the polling interval in seconds. The range is from 120
to 6000 seconds. The default is 300 seconds (5 minutes).
Defaults Disabled
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Replacement command for the S4820T. Replaces the enable xfp-power-updates
command.
8.3.11.4 Replacement command for the Z9000. Replaces the enable xfp-power-updates
command
8.3.10.0 Replacement command for the S4810 only. Replaces the enable xfp-power-
updates command.
Usage Information To enable polling and to congure the polling frequency, use this command.
Control and Monitoring 97