Users Guide
Field Description
the secondary RPM until failover occurs, and the routing table on line cards is cleared
during failover.
• the status of auto booting the RPM (the redundancy disable-auto-reboot
command)
• the parameter for auto failover limit control (the redundancy auto-failover-
limit command)
•
RPM Failover
Record
Displays the following information:
• RPM failover counter (to reset the counter, use the redundancy reset-
counter command)
• the time and date of the last RPM failover
• the reason for the last RPM failover
Last Data Sync
Record
Displays the data sync information and the timestamp for the data sync:
• Start-up Config is the contents of the startup-config file.
• Line Card Config is the line card types configured and interfaces on those line cards.
• Runtime Event Log is the contents of the Event log.
• Running Config is the current running-config.
This field only appears when you enter the command from the Primary RPM.
Example
Dell# show redundancy
-- RPM Status --
------------------------------------------------
RPM Slot ID: 1
RPM Redundancy Role: Primary
RPM State: Active
RPM SW Version: 7.5.1.0
Link to Peer: Up
-- PEER RPM Status --
------------------------------------------------
RPM State: Standby
RPM SW Version: 7.5.1.0
-- RPM Redundancy Configuration --
------------------------------------------------
Primary RPM: rpm0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot RPM: Enabled
Auto failover limit: 3 times in 60 minutes
-- RPM Failover Record --
------------------------------------------------
Failover Count: 1
Last failover timestamp: Jul 13 2007 21:25:32
Last failover Reason: User request
-- Last Data Block Sync Record: --
------------------------------------------------
Line Card Config: succeeded Jul 13 2007 21:28:53
Start-up Config: succeeded Jul 13 2007 21:28:53
SFM Config State: succeeded Jul 13 2007 21:28:53
Runtime Event Log: succeeded Jul 13 2007 21:28:53
High Availability (HA)