Users Guide

------------------------------------------------------------------------------
1 Member not present
2 Management online S4048-ON S4048-ON 1-0(0-4160) 72
3 Member not present
4 Member not present
5 Member not present
6 Member not present
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
-----------------------------------------------------------
2 1 up AC up 7048
2 2 down UNKNOWN down 0
-- Fan Status --
Unit Bay TrayStatus Fan0 Speed Fan1 Speed
----------------------------------------------------
2 1 up up 7021 up 6971
2 2 up up 7021 up 7072
2 3 up up 6971 up 7021
Speed in RPM
show tech-support
Display a collection of data from other show commands, necessary for Dell Networking technical support to perform troubleshooting.
Syntax
show tech-support [stack-unit unit-id | page]
Parameters
stack-unit (OPTIONAL) Enter the keywords stack-unit to view CPU memory usage for the
stack member designated by unit-id.
page (OPTIONAL) Enter the keyword page to view 24 lines of text at a time. Press the
SPACE BAR to view the next 24 lines. Press the ENTER key to view the next line of text.
When using the pipe command ( | ), enter one of these keywords to filter command
output. For details about filtering commands, refer to CLI Basics.
save Enter the keyword save to save the command output.
flash: Save to local flash drive (flash://filename. A maximum of 20 characters.
Command Modes EXEC Privilege
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.8.1.0 Introduced save to the file options.
Control and Monitoring 145