Administrator Guide

Version Description
9.8(1.0) Introduced on the Z9100ON.
9.3.0.0 Introduced on the S6000.
9.2(1.0) Introduced on the Z9500.
Usage
Information
To enable routing of RRoCE packets, the VLAN ID is mapped to the default VLAN ID of 4095 and this
mapping is performed using VLAN translation. After VLAN translation, the RRoCE packets are considered
in the same manner as normal IP packets that received on L3 interface and routed in the egress direction.
At the egress interface, the VLAN ID is appended to the packet and transmitted out of the interface as a
tagged packet with the dot1Q value preserved. The dot1Q value is preserved only for egress interfaces
that are associated with a VLAN or a lite-subinterface . If a Layer 3 interface is configured without the
encapsulation 802.1Q VLAN ID or is an untagged interface in a VLAN , the dot1Q value is not preserved .
errdisable recovery cause
Enable automatic recovery of an interface from the Err-disabled state.
Syntax
errdisable recovery cause {bpduguard | fefd | maclearnlimit | arp-
inspection}
To disable the automatic recovery, use the no errdisable recovery cause {bpduguard |
fefd | maclearnlimit | arp-inspection} command.
Parameters
bpduguard Enter the keyword bpduguard to enable the timer to recover the interface from
BPDU Guard error.
fefd Enter the keyword fefd to enable the timer to recover the interface from FEFD
error.
maclearnlimit Enter the keyword maclearnlimit to enable the timer to recover the interface
from MAC learning limit error.
arp-inspection Enter the keyword arp-inspection to enable the timer to recover the interface
from an arp-inspection error.
Defaults Disabled
Command Modes CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms, see the relevant Dell
EMC Networking OS Command Line Reference Guide.
Version Description
9.14(1.0) Introduced arp-inspection option.
9.14(0.0) Introduced on the platforms S4048ON, S6100ON, Z9100ON, S4048T-ON,
S3048ON, S6000, S6010ON, S5048F-ON, FN-IOM and MXL.
9.13(0.2P2) Introduced on the S3100.
Usage
Information
This command has to be configured before the interface moves to Err-disabled state. If not, the recovery
action is not performed.
Related
Commands
errdisable recovery interval Configure recovery timer interval for an interface.
Interfaces 619