Users Guide
View link-bundle monitoring threshold configuration
OS10(config)# do show running-configuration
link-bundle-trigger-threshold 10
!
...
Show link-bundle utilization
OS10(config)# do show link-bundle-utilization
Link-bundle trigger threshold - 10
Alarm commands
alarm acknowledge
Acknowledges an active alarm.
Syntax
alarm acknowledge sequence-number
Parameters
● sequence-number — Acknowledge the alarm corresponding to the sequence number.
Default Not configured
Command Mode EXEC
Usage
Information
Use the show alarm command to view all active alarms. Use active alarm sequence numbers to
acknowledge specific alarms.
Example
OS10# alarm acknowledge 1
Supported
Releases
10.4.3 or later
event severity-profile
Configures a severity profile to change the severity of events, or turn off event notifications.
Syntax
event severity-profile {default | profile-name}
Parameters profile-name—Name of the custom severity profile, a maximum of 64 characters. The file
extension, .xml is optional.
Default Default.xml
Command Mode EXEC
Usage
Information
Configures a severity profile to change the characteristics of events. If you configure a custom profile,
the profile applies on top of the default profile. Restart the system for the changes to take effect. The
system restart ensures that the existing stateful events are tagged appropriately based on the newly
applied severity profile. Severity profiles are stored in the severity-profile:// partition. This partition
includes a factory default severity profile, default.xml. You cannot edit or delete the default and active
severity profiles.
Example
OS10# event severity-profile MySevPro_1
%Notice: Severity profile will be active after system restart
Supported
Releases
10.5.0 or later
1810 Troubleshoot Dell EMC SmartFabric OS10