Reference Guide

Disable console logging and reset the minimum logging severity to the default in CONFIGURATION mode.
no logging console severity
Disable log-le logging and reset the minimum logging severity to the default in CONFIGURATION mode.
no logging log-file severity
Disable monitor logging and reset the minimum logging severity to the default in CONFIGURATION mode.
no logging monitor severity
Disable server logging and reset the minimum logging severity to the default in CONFIGURATION mode.
no logging server severity
Re-enable any logging command in CONFIGURATION mode.
no logging enable
Enable server logging for log notice
OS10(config)# logging server dell.com severity log-notice
View system logs
The system log-le contains system event and alarm logs.
Use the show trace command to view the current syslog le. All event and alarm information is sent to the syslog server, if one is
congured.
The show logging command accepts the following parameters:
log-file — Provides a detailed log including both software and hardware saved to a le.
process-names — Provides a list of all processes currently running which can be ltered based on the process-name.
View logging log-le
OS10# show logging log-file
Jun 1 05:01:46 %Node.1-Unit.1:PRI:OS10 %log-notice:ETL_SERVICE_UP: ETL service
is up
Jun 1 05:02:06 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_UNIT_DETECTED: Unit pres
ent:Unit 1#003
Jun 1 05:02:09 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_PSU_DETECTED: Power Supp
ly Unit present:PSU 1#003
Jun 1 05:02:09 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_PSU_DETECTED: Power Supp
ly Unit present:PSU 2#003
Jun 1 05:02:09 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_FAN_TRAY_DETECTED: Fan t
ray present:Fan tray 1#003
Jun 1 05:02:09 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_FAN_TRAY_DETECTED: Fan t
ray present:Fan tray 2#003
Jun 1 05:02:09 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_FAN_TRAY_DETECTED: Fan t
ray present:Fan tray 3#003
Jun 1 05:02:09 %Node.1-Unit.1:PRI:OS10 %log-crit:EQM_FAN_AIRFLOW_MISMATCH: MAJO
R ALARM: FAN AIRFLOW MISMATCH: SET: One or more fans have mismatching or unknown
airflow directions#003
Jun 1 05:02:10 %Node.1-Unit.1:PRI:OS10 %log-notice:NDM_SERVICE_UP: NDM Service
Ready!
Jun 1 05:02:10 %Node.1-Unit.1:PRI:OS10 %log-notice:SU_SERVICE_UP: Software upgr
ade service is up:software upgrade service up
Jun 1 05:02:10 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_UNIT_CHECKIN: Check-in n
otification from unit:Unit 1 (type S6000)#003
Jun 1 05:02:10 %Node.1-Unit.1:PRI:OS10 %log-notice:EQM_UNIT_UP: Unit is up:Unit
1#003
Jun 1 05:02:10 %Node.1-Unit.1:PRI:OS10 %log-notice:IFM_ASTATE_UP: Interface adm
in state up.:mgmt1/1/1
Jun 1 05:02:10 %Node.1-Unit.1:PRI:OS10 %log-notice:IFM_ASTATE_UP: Interface adm
in state up.:vlan1
--More--
Troubleshoot OS10
585