Reference Guide
Defaults 30
Command Mode CONFIGURATION
Usage Information
The polling interval for an interface is the number of seconds between successive samples of counters sent to the
collector. You can congure the duration at which the interface statistics counter should be polled. Use the no
version of the command to reset the interval time to the default value.
Example
OS10(conf)# sflow polling-interval 200
Supported Releases 10.3.0E or later
sow sample-rate
Congures the sampling rate.
Syntax
sflow sample-rate value
Parameter value — Enter the packet sample rate (4096 to 65535; default 32768).
Default 32768
Command Mode CONFIGURATION
Usage Information
Sampling rate is the number of packets skipped before the sample is taken. For example, if the sampling rate is
specied as 4096, then 1 sample is generated for every 4096 packets observed. Use the no version of the
command to reset the sampling rate to the default value.
Example
OS10(conf)# sflow sample-rate 4096
Supported Releases 10.3.0E or later
show sow
Displays current sFlow conguration for all interfaces or by a specic interface type.
Syntax
show sflow [interface type]
Parameter interface type — (Optional) Enter either ethernet or port-channel for the interface type.
Command Mode EXEC
Usage Information
OS10 does not support statistics for UDP packets dropped and samples received from hardware.
Example
OS10# show sflow
sFlow services are enabled
Management Interface sFlow services are disabled
Global default sampling rate: 32768
Global default counter polling interval: 30
Global default extended maximum header size: 128 bytes
Global extended information enabled: none
1 collector(s) configured
Collector IP addr:10.16.151.245 Agent IP addr:10.16.132.181 UDP port:6343
VRF:Default
31722 UDP packets exported
552 sFlow