Reference Guide

Command Mode EXEC
Usage Information In an iSCSI session, Target is the storage device, and Initiator is the server connected to the storage device.
Example
OS10# show iscsi session
Example (detailed)
OS10# show iscsi session detailed
Session 1
------------------------------------------------
Target:iqn.2001-05.com.equallogic:0-8a0906-00851a00c-98326939fba510a1-517
Initiator:iqn.1991-05.com.microsoft:win-rlkpjo4jun2
Up Time:00:00:18:12(DD:HH:MM:SS)
Time for aging out:29:23:59:35(DD:HH:MM:SS)
ISID:400001370000
Initiator Initiator Target Target Connection
IP Address TCP Port IP Address TCP Port ID
----------------------------------------------------------
10.10.10.210 54748 10.10.10.40 3260 1
Session 2
------------------------------------------------
Target:iqn.2001-05.com.equallogic:0-8a0906-01251a00c-8ab26939fbd510a1-518
Initiator:iqn.1991-05.com.microsoft:win-rlkpjo4jun2
Up Time:00:00:16:02(DD:HH:MM:SS)
Time for aging out:29:23:59:35(DD:HH:MM:SS)
ISID:400001370000
Initiator Initiator Target Target Connection
IP Address TCP Port IP Address TCP Port ID
----------------------------------------------------------
10.10.10.210 54835 10.10.10.40 3260 1
Supported Releases 10.3.0E or later
show iscsi storage-devices
Displays information about the storage arrays directly attached to OS10 ports.
Syntax
show iscsi storage-devices
Parameters None
Command Mode EXEC
Usage Information The command output displays the storage device connected to each switch port and whether iSCSI automatically
detects it.
Example
OS10# show iscsi storage-devices
Interface Name Storage Device Name Auto Detected Status
-----------------------------------------------------------
ethernet1/1/23 EQL-MEM true
Supported Releases 10.3.0E or later
Converged network DCB example
A converged data center network carries multiple trac types (SAN, server, and LAN) that are sensitive to dierent aspects of data
transmission. For example, storage trac is sensitive to packet loss, while server trac is latency-sensitive. In a single converged link, all
trac types coexist without imposing serious restrictions on others' performance. DCB allows iSCSI and FCoE SAN trac to co-exist with
server and LAN trac on the same network. DCB features reduce or avoid dropped frames, retransmission, and network congestion.
566
Converged data center services