Users Guide

Version Description
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.5.1.0 Added support for 4-port 40G line cards on ExaScale.
8.1.1.0 Introduced on the E-Series ExaScale.
7.8.1.0 Output augmented with diagnostic data for pluggable media.
7.7.1.0 Removed three elds in the output: Vendor Name, Vendor OUI, and Vendor PN.
7.6.1.0 Introduced on the C-Series and S-Series.
6.5.4.0 Introduced on the E-Series.
Usage Information The following describes the show interfaces transceiver command shown in the following
example.
Line Description
Rx Power
measurement type
Output depends on the vendor, typically either “Average” or “OMA” (Receiver
optical modulation amplitude).
Temp High Alarm
threshold
Factory-dened setting, typically in Centigrade. Value diers between SFPs and
SFP+.
Voltage High Alarm
threshold
Displays the interface index number used by SNMP to identify the interface.
Bias High Alarm
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power High
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
RX Power High
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp Low Alarm
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage Low Alarm
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias Low Alarm
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power Low
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
RX Power Low
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp High Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage High
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Interfaces
675