Users Guide
Field Description
RPM Redundancy
Conguration
Displays the following information:
• which RPM is the preferred Primary on next boot (the redundancy
primary command)
• the data sync method congured (the redundancy synchronize
command)
• the failover type (you cannot change this type; it is software-dependent). Hot
Failover means that the running conguration and routing table are applied on
secondary RPM. Fast Failover means that the running conguration is not
applied on the secondary RPM until failover occurs, and the routing table on
line cards is cleared during failover.
• the status of auto booting the RPM (the redundancy disable-auto-
reboot command)
• the parameter for auto failover limit control (the redundancy auto-
failover-limit command)
•
RPM Failover
Record
Displays the following information:
• RPM failover counter (to reset the counter, use the redundancy reset-
counter command)
• the time and date of the last RPM failover
• the reason for the last RPM failover
Last Data Sync
Record
Displays the data sync information and the timestamp for the data sync:
• Start-up Cong is the contents of the startup-cong le.
• Line Card Cong is the line card types congured and interfaces on those line
cards.
• Runtime Event Log is the contents of the Event log.
• Running Cong is the current running-cong.
This eld only appears when you enter the command from the Primary RPM.
Example
Dell#show redundancy
-- RPM Status --
------------------------------------------------
RPM Slot ID: 1
RPM Redundancy Role: Primary
RPM State: Active
RPM SW Version: 7.5.1.0
Link to Peer: Up
-- PEER RPM Status --
------------------------------------------------
RPM State: Standby
RPM SW Version: 7.5.1.0
-- RPM Redundancy Configuration --
------------------------------------------------
Primary RPM: rpm0
Auto Data Sync: Full
Failover Type: Hot Failover
Auto reboot RPM: Enabled
Auto failover limit: 3 times in 60 minutes
598
High Availability (HA)