Users Guide

ethernet cfm mep
Create an MEP.
Syntax
ethernet cfm mep {up-mep | down-mep} domain {name | level} ma-name name
mepid mep-id
Parameters
[up-mep | down-
mep]
Specify whether the MEP is up or down facing.
Up-MEP: monitors the forwarding path internal to a bridge on the customer or
provider edge; on Dell Networking systems, the internal forwarding path is
eectively the switch fabric and forwarding engine.
Down-MEP: monitors the forwarding path external to another bridge.
domain [name |
level]
Enter the keyword domain and then enter the domain name or domain level.
ma-name name Enter the keyword ma-name and then enter the name of the maintenance
association.
mepid mep-id Enter an MEP ID. The range is from 1 to 8191.
Defaults none
Command Modes INTERFACE
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.3.1.0 Introduced on the S-Series.
ethernet cfm mip
Create a maintenance intermediate point (MIP).
Syntax
ethernet cfm mip domain {name | level} ma-name name
Parameters
domain [name |
level]
Enter the keyword domain then the domain name or domain level.
ma-name name Enter the keyword ma-name then the name of the maintenance association.
Defaults none
802.1ag
163