Users Guide
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on the E-Series ExaScale. C-Series and S-Series accept both bytes of
the 2-byte S-Tag TPID.
8.2.1.0 Introduced on the E-Series ExaScale.
7.6.1.0 Introduced on the C-Series and S-Series.
E-Series original
Command
Usage Information
For specic interoperability limitations regarding the S-Tag TPID, see the Dell Networking OS Conguration
Guide.
The four characters you may enter are shown in the following table.
Number Resulting TPID
1 0x0001
10 0x0010
81 0x0081
8100 0x8100
Related Commands
portmode hybrid — sets a port (physical ports only) to accept both tagged and untagged frames. A port
congured this way is identied as a hybrid port in report displays.
vlan-stack trunk — species a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.
vlan-stack trunk
Specify a Layer 2 port or port channel as a trunk port to the stackable VLAN network.
Syntax
vlan-stack trunk
1568