Users Guide
Usage Information
Resetting the management unit is not allowed, and an error message displays if you try to do so. Resetting is
a soft reboot, including ushing the forwarding tables.
Starting with Dell Networking OS version 7.8.1.0, you can run this command directly on the stack standby
unit (standby master) to reset the standby. You cannot reset any other unit from the standby unit.
Example
Dell#reset stack-unit 4
Dell#00:15:00: %STKUNIT1-M:CP %CHMGR-5-STACKUNIT_RESET: stack-unit 4 being
reset
00:15:01: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 4 down - reset
00:15:01: %STKUNIT1-M:CP %IFMGR-1-DEL_PORT: Removed port: Gi 4/1-4/48, Te
4/51-4/52,
00:15:01: %STKUNIT2-S:CP %IFMGR-1-DEL_PORT: Removed port: Gi 4/1-4/48, Te
4/51-4/52,
Dell#00:15:08: %S3048-ON:1 %IFAGT-5-STACK_PORT_LINK_DOWN: Changed stack
port state to down: 1/49
00:15:08: %STKUNIT1-M:CP %CHMGR-2-STACKUNIT_DOWN: stack-unit 4 down - card
removed
Dell#
Related Commands
• reload – reboots Dell Networking OS.
show redundancy
Display the current redundancy conguration (status of automatic reboot conguration on stack management unit).
Syntax
show redundancy
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.7.0 Introduced on the S4810.
8.3.11.1 Introduced on the Z9000.
Usage Information To modify your results, use the show redundancy [pipe] command, as follows: