Users Guide

Message ID Trap Type Trap Option
%CHMGR-2-PEM_PRBLM: Major
alarm: problem with power
entry module %s
CHM_PWRSRC_CLR ENVMON SUPPLY
%CHMGR-5-PEM_OK: Major alarm
cleared: power entry module
%s is good
CHM_MAJ_ALARM_PS ENVMON SUPPLY
%CHMGR-0-MAJOR_PS: Major
alarm: insufficient power %s
CHM_MAJ_ALARM_PS_CLR ENVMON SUPPLY
%CHMGR-5-MAJOR_PS_CLR: major
alarm cleared: sufficient
power
CHM_MIN_ALARM_PS ENVMON SUPPLY
%CHMGR-1-MINOR_PS: Minor
alarm: power supply non-
redundant
CHM_MIN_ALARM_PS_CLR ENVMON SUPPLY
%CHMGR-5-MINOR_PS_CLR: Minor
alarm cleared: power supply
redundant
CHM_MIN_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MINOR_TEMP: Minor
alarm: chassis temperature
CHM_MIN_ALRM_TEMP_CLR ENVMON TEMP
%CHMRG-5-MINOR_TEMP_CLR:
Minor alarm cleared: chassis
temperature normal (%s %d
temperature is within
threshold of %dC)
CHM_MAJ_ALRM_TEMP ENVMON TEMP
%CHMGR-2-MAJOR_TEMP: Major
alarm: chassis temperature
high (%s temperature reaches
or exceeds threshold of %dC)
CHM_MAJ_ALRM_TEMP_CLR ENVMON TEMP
%CHMGR-2-MAJOR_TEMP_CLR:
Major alarm cleared: chassis
temperature lower (%s %d
temperature is within
threshold of %dC)
CHM_FANTRAY_BAD ENVMON FAN
For E1200: %CHMGR-2-
FAN_TRAY_BAD: Major alarm:
fan tray %d is missing or
down
SNMP Traps
1471