Users Guide
Version Description
7.6.1.0 Introduced on the C-Series.
6.5.1.0 Expanded the no form of the command to mirror the syntax used to congure.
6.2.1.1 Introduced on the E-Series.
Usage Information
You can congure up to two sFlow collectors (IPv4 or IPv6). If two collectors are congured, trac samples
are sent to both.
The sFlow agent address is carried in a eld in SFlow packets and is used by the collector to identify the
sFlow agent.
In sFlow, the agent address is a single invariant IPv4 or IPv6 address used to identify the agent to the
collector. It is usually assigned the address of a loopback interface on the agent, which provides invariance.
The agent address is carried as a eld in the payload of the sFlow packets.
As part of the sFlow-MIB, if the SNMP request originates from a congured collector, Dell Networking OS
returns the corresponding congured agent IP in the MIB requests. Dell Networking OS checks to ensure
that two entries are not congured for the same collector IP with a dierent agent IP. Should that happen,
Dell Networking OS generates the following error: %Error: Different agent-addr attempted
for an existing collector.
Example
Dell(conf)#sflow collector 10.1.1.25 agent-addr 10.1.1.10 vrf management
sow enable (Global)
Enable sFlow globally.
Syntax
sflow enable
To disable sFlow, use the no sflow enable command.
Defaults Disabled.
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
sFlow