Users Guide
Parameters
vrf management Enter the keyword vrf followed by the keyword management to specify a
management VRF that is used by the TELNET server.
vrf vrf-name Enter the keyword vrf and then the name of the VRF to specify the VRF that is
used by the TELNET server.
Defaults Disabled
Command Modes CONFIGURATION
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.5(0.0) Introduced on the Z9500.
9.4.(0.0) Introduced on the S-Series and Z9000.
Usage Information You can enable the TELNET server on either a management VRF or a user-dened VRF but not both. If you
do not specify a VRF name, then the TELNET server is enabled on the default VRF.
Example
Dell(conf)#ip telnet server vrf vrf1
Dell(conf)#no ip telnet server vrf
Dell(conf)#ip telnet server vrf management
Dell(conf)#no ip telnet server vrf
ip telnet source-interface
Set an interface’s IP address as the source address in outgoing packets for Telnet sessions.
Syntax
ip telnet source-interface interface
To return to the default setting, use the no ip telnet source-interface [interface]
command.
Parameters
interface Enter the following keywords and slot/port or number information:
• For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet
then the slot/port information.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
•
For Loopback interfaces, enter the keyword loopback then a number from
zero (0) to 16383.
• For a port channel interface, enter the keywords port-channel then a
number. The range is from 1 to 128.
• For VLAN interface, enter the keyword vlan then a number from 1 to 4094.
108