Technical Specifications
This chapter lists the S3048–ON specifications.
NOTE: Operate the system at an ambient temperature not higher than 113°F
(45°C).
CAUTION: Lithium Battery Caution: To avoid the possibility of an explosion,
always replace the battery correctly.
NOTE: Replace the battery only with the same or an equivalent type. Dispose of
the batteries according to the manufacturer's instructions.
Table 3. S3048–ON Chassis Physical Design
Parameter Specifications
Height 1.73 inches (44 mm)
Width 17.09 inches (434 mm)
Depth 12.60 inches (320 mm)
Chassis weight with factory-installed
components
21.7 pounds (approx.) (9.86 kg)
Rack clearance required
Front: 5 inches (12.7 cm)
Rear: 5 inches (12.7 cm)
Table 4. Environmental Parameters
Parameter Specifications
Operating temperature 32° to 113°F (0° to 45°C)
Operating humidity 5 to 85 percent (RH), non-condensing
Storage temperature –40° to 158°F (–40° to 70°C)
Storage and non-operating humidity 5 to 95 percent (RH), non-condensing
Maximum thermal output 1153.265 BTH/hr
Technical Specifications 30