Accessing the Console
The RS-232 console port is on the right-hand side of the S3048–ON system as you
face the PSU side of the chassis, as shown in the following illustration.
Figure 9. S3048–ON RS-232 Console Port
1 RS-232 Console Port
NOTE: You must have a password configured on a virtual terminal line before
you can Telnet into the S3048–ON system. Therefore, use a console
connection when connecting to the system for the first time. Before starting this
procedure, be sure that you have a terminal emulation program already installed
on your PC.
1 Install an RJ-45 copper cable into the console port. Use a rollover cable to
connect the S3048–ON console port to a terminal server.
2 Connect the other end of the cable to the DTE terminal server.
3 Set the default terminal settings as follows.
• 115200 baud rate
• No parity
• 8 data bits
• 1 stop bit
• No flow control
Dell Networking OS 22