Users Guide
Port Monitoring
Port monitoring is supported on both physical and logical interfaces, such as VLAN and port-channel interfaces. The source port (MD) with
monitored trac and the destination ports (MG) to which an analyzer can be attached must be on the same switch. You can congure up
to 128 source ports in a monitoring session. Only one destination port is supported in a monitoring session. The platform supports multiple
source-destination statements in a single monitor session.
The maximum number of source ports that can be supported in a session is 128.
The maximum number of destination ports that can be supported depends on the port mirroring directions as follows:
• 4 per port pipe, if the four destination ports mirror in one direction, either rx or tx.
• 2 per port pipe, if the two destination ports mirror in bidirection.
• 3 per port pipe, if one of the destination port mirrors bidirection and the other two ports mirror in one direction (either rx or tx).
In the following examples, ports 1/13, 1/14, 1/15, and 1/16 all belong to the same port-pipe. They are pointing to four dierent destinations
(1/1, 1/2, 1/3, and 1/37). Now it is not possible for another source port from the same port-pipe (for example, 1/17) to point to another new
destination (for example, 1/4). If you attempt to congure another destination (to create 5 MG port), this message displays: % Error
will be thrown in case of RPM and ERPM features.
Example of Changing the Destination Port in a Monitoring Session
Dell(conf-mon-sess-5)#do show moni session
SessID Source Destination Dir Mode Source IP Dest IP
------ ------ ----------- --- ---- --------- --------
1 Gi 1/1 Gi 2/1 both Port N/A N/A
2 Gi 1/1 Gi 2/2 both Port N/A N/A
3 Gi 1/1 Gi 2/3 both Port N/A N/A
4 Gi 1/1 Gi 2/4 both Port N/A N/A
5 Gi 1/1 Gi 2/5 both Port N/A N/A
Dell(conf-mon-sess-5)#
Dell(conf)#mon ses 300
Dell(conf-mon-sess-300)#source gig 1/17 destination gig 1/4 direction tx
% Error: Exceeding max MG ports for this MD port pipe.
Dell(conf-mon-sess-300)#
Dell(conf-mon-sess-300)#source gig 1/17 destination gig 1/1 direction tx
Dell(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 Gi 1/13 Gi 2/1 rx interface Port-based
10 Gi 1/14 Gi 2/2 rx interface Port-based
20 Gi 1/15 Gi 2/3 rx interface Port-based
30 Gi 1/16 Gi 2/7 rx interface Port-based
300 Gi 1/17 Gi 1/1 tx interface Port-based
Dell(conf-mon-sess-300)#
Example of Conguring Another Monitoring Session with a Previously Used Destination Port
Dell(conf)#mon ses 300
Dell(conf-mon-sess-300)#source Gig 1/17 destination Gig 1/4 direction tx
% Error: Exceeding max MG ports for this MD port pipe.
Dell(conf-mon-sess-300)#
Dell(conf-mon-sess-300)#source Gig 1/17 destination Gig 1/1 direction tx
Dell(conf-mon-sess-300)#do show mon session
SessionID Source Destination Direction Mode Type
--------- ------ ----------- --------- ---- ----
0 Gi 1/13 Gi 1/1 rx interface Port-based
10 Gi 1/14 Gi 1/2 rx interface Port-based
20 Gi 1/15 Gi 1/3 rx interface Port-based
30 Gi 1/16 Gi 1/7 rx interface Port-based
300 Gi 1/17 Gi 1/1 tx interface Port-based
554