Administrator Guide

By default, physical interfaces are disabled (shutdown) and are not assigned to an IP address or switchport. To
place an interface in Layer 2 mode, ensure that the interface’s configuration does not contain an IP address and
enter the
switchport command.
You can create up to 64 tunnel interfaces. The tunnel is added as a logical interface with no default configuration.
To delete a tunnel interface, use the
no interface tunnel tunnel-id command.
The tunnel interface operates as an ECMP (equal cost multi path) only when the next hop to the tunnel
destination is over a physical interface. If you select any other interface as the next hop to the tunnel destination,
the tunnel interface does not operate as an ECMP.
Example
DellEMC(conf)# int tengigabitethernet 1/10
DellEMC(conf-if-gi-1/10)# exit
DellEMC(conf)#
Related
Commands
interface loopback — configure a Loopback interface.
interface null — configure a Null interface.
interface port-channel — configure a port channel.
interface vlan — configure a VLAN.
interface group
Create or delete group of VLANs with a single command. You can also use this command to apply a set of configurations on a group of
interfaces.
Syntax
interface group [interface | vlan vlanid {- vlanid } ]
To delete a range of VLANs, use the following command:
no interface group vlan vlanid {- vlanid}
Parameters
interface,
interface,...
Enter the keywords interface group and one of the interfaces — slot/port or VLAN
number. Select the range of interfaces for bulk configuration. Spaces are not required
between the commas. Comma-separated ranges can include VLANs and physical
interfaces.
Enter the member VLANs using VLAN IDs (separated by commas), a range of VLAN IDs
(separated by a hyphen), a single VLAN ID, or a combination. For example: VLAN IDs
(comma-separated): 3, 4, 6. Range (hyphen-separated): 5-10.
Slot/Port information need not contain a space before and after the dash. For example,
both of the following commands are valid: interface group gigabitethernet
1/1 - 1/5; interface group gigabitethernet 1/1-1/5.
For a 1-GigabitEthernet interface, enter the keyword GigabitEthernet then the
slot/port information.
For a 10-Gigabit Ethernet interface, enter the keyword TenGigabitEthernet then
the slot/port information.
For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
Interfaces 603