Administrator Guide

errdisable recovery cause
Enable automatic recovery of an interface from the Err-disabled state.
Syntax
errdisable recovery cause {bpduguard | fefd | maclearnlimit | arp-inspection}
To disable the automatic recovery, use the no errdisable recovery cause {bpduguard | fefd |
maclearnlimit | arp-inspection} command.
Parameters
bpduguard Enter the keyword bpduguard to enable the timer to recover the interface from BPDU
Guard error.
fefd Enter the keyword fefd to enable the timer to recover the interface from FEFD error.
maclearnlimit Enter the keyword maclearnlimit to enable the timer to recover the interface from
MAC learning limit error.
arp-inspection Enter the keyword arp-inspection to enable the timer to recover the interface from
an arp-inspection error.
Defaults Disabled
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.14(1.0) Introduced arp-inspection option.
9.14(0.0) Introduced on the platforms S4048–ON, S6100–ON, Z9100–ON, S4048T-ON, S3048–
ON, S6000, S6010–ON, S5048F-ON, FN-IOM and MXL.
9.13(0.2P2) Introduced on the S3100.
Usage Information
This command has to be configured before the interface moves to Err-disabled state. If not, the recovery action is
not performed.
Related
Commands
errdisable recovery interval— Configure recovery timer interval for an interface.
errdisable recovery interval
Configure recovery time interval to move an interface from the Err-disabled state.
Syntax
errdisable recovery interval seconds
To remove the configured recovery time interval, use the no errdisable recovery interval seconds
command.
Parameters
interval
seconds
Enter the keyword interval and the number of seconds to recover the interface from
Err-disabled state. The range is from 30 to 86,400 seconds. The default is 300 seconds.
Defaults 300 seconds.
Command Modes CONFIGURATION
Command History
This guide is platform-specific. For command information about other platforms, see the relevant Dell EMC
Networking OS Command Line Reference Guide.
Version Description
9.14(0.0) Introduced on the platforms S4048–ON, S6100–ON, Z9100–ON, S4048T-ON, S3048–
ON, S6000, S6010–ON, S5048F-ON, FN-IOM, and MXL.
9.13(0.2P2) Introduced on the S3100.
598 Interfaces