Users Guide

Table Of Contents
Parameters None
Default None
Command Mode EXEC
Usage Information None
Example
show alarms acknowledged
Sq No Severity Name
Timestamp Source
----- -------- ------------------------------
--------------------------- --------------
100071 warning EQM_FAN_FAULT_MINOR Tue Jul 23 13:53:47
2019 /psu/1/fan/1
100072 critical EQM_FAN_FAULT_MAJOR Tue Jul 23 13:53:47
2019 /psu/1
Supported Releases 10.2.0E or later
show alarms details
Displays details about active alarms.
Syntax
show alarms details
Parameters None
Default None
Command Mode EXEC
Usage Information The output of the show alarms details command indicates if an alarm is acknowledged or not. If an alarm is
not acknowledged, the Acknowledged eld is set to false and the Ack-time value is empty. If an alarm is
acknowledged, the
Acknowledged eld is set to true and the system displays the time the alarm was
acknowledged.
Example
Alarm is not acknowledged:
OS10# show alarms details
Active-alarm details - 732
-------------------------------------------
Sequence Number: 732
Severity: critical
Source: /psu/2
Name: EQM_MORE_PSU_FAULT
Description: psu 2 is not working correctly
Raise-time: Mon Jul 29 06:12:30 2019
Ack-time:
New: true
Acknowledged: false
-------------------------------------------
Alarm is acknowledged:
OS10# show alarms details
Active-alarm details - 732
-------------------------------------------
Sequence Number: 732
Severity: critical
Source: /psu/2
Name: EQM_MORE_PSU_FAULT
Troubleshoot OS10 1361