Users Guide

Table Of Contents
Usage Information
On the Z9100–ON and Z9264F–ON platforms, interfaces are shared across port pipes and port pipes are shared
across Memory Management Units (MMUs). As interfaces span port pipes, Dell EMC Networking recommends
using interfaces from same port pipes for both ingress and egress for optimal performance. To nd the port to
port-pipe and MMU mapping, use the show qos port-map details command.
Example
Z9100–ON switch:
OS10# show qos port-map details
---------------------------------------------------------------------------
Interface Port Pipe Ingress MMU Egress MMU Oper Status
---------------------------------------------------------------------------
Eth 1/1/1 1 2, 3 0, 2 up
Eth 1/1/2 1 2, 3 0, 2 up
Eth 1/1/3 1 2, 3 0, 2 up
Eth 1/1/4 1 2, 3 0, 2 up
Eth 1/1/5 2 2, 3 1, 3 up
Eth 1/1/6 2 2, 3 1, 3 up
Eth 1/1/7 2 2, 3 1, 3 up
Eth 1/1/8 2 2, 3 1, 3 up
Eth 1/1/9 1 2, 3 0, 2 up
Eth 1/1/10 1 2, 3 0, 2 up
Eth 1/1/11 1 2, 3 0, 2 up
Eth 1/1/12 1 2, 3 0, 2 up
Eth 1/1/13 2 2, 3 1, 3 down
Eth 1/1/14 2 2, 3 1, 3 down
Eth 1/1/15 2 2, 3 1, 3 down
Eth 1/1/16 2 2, 3 1, 3 down
Eth 1/1/17 3 0, 1 1, 3 down
Eth 1/1/18 3 0, 1 1, 3 down
Eth 1/1/19 3 0, 1 1, 3 down
Eth 1/1/20 3 0, 1 1, 3 down
Eth 1/1/21 0 0, 1 0, 2 down
Eth 1/1/22 0 0, 1 0, 2 down
Eth 1/1/23 0 0, 1 0, 2 down
Eth 1/1/24 0 0, 1 0, 2 down
Eth 1/1/25 3 0, 1 1, 3 up
Eth 1/1/26 3 0, 1 1, 3 down
Quality of service