Administrator Guide
Version Description
E-Series Original command.
Example
Dell# show debug
Generic IP:
IP packet debugging is on for
ManagementEthernet 1/1
Port-channel 1-2
Port-channel 5
GigabitEthernet 4/1-4/3,4/5-4/6,4/10-4/11,20
GigabitEthernet 5/1-5/3,5/5-5/6,5/10-5/11,15,17,19,21
ICMP packet debugging is on for
GigabitEthernet 5/1,5/2,5/4,5/6,5/8,5/10,5/12,5/14,5/16
Dell#
show environment
View system component status (for example, temperature or voltage).
Syntax
show environment [all | fan | pem | stack-unit unit-id | thermal-sensor ]
Parameters
all Enter the keyword all to view all components.
fan Enter the keyword fan to view information on the fans. The output of this command is
chassis-dependent.
pem Enter the keyword pem to view only information on power entry modules.
stack-unit unit-id Enter the keywords stack-unit then the unit-id to display information on a specic
stack member.
thermal-sensor Enter the keywords thermal-sensor to view information on thermal sensors.
Command Modes
• EXEC
• EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.11(2.1P1) The CLI has been enhanced to show the power, average power and average power start
time.
9.10(0.1) Introduced on the S6010-ON and S4048T-ON.
9.10(0.0) Introduced on the S3148.
9.10(0.0) Introduced on the S6100-ON.
9.8(2.0) Introduced on the S3100 series.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
Control and Monitoring 131