Users Guide

Line Description
Rx Power
measurement type
Output depends on the vendor, typically either “Average” or “OMA” (Receiver optical
modulation amplitude).
Temp High Alarm
threshold
Factory-dened setting, typically in Centigrade. Value diers between SFPs and SFP+.
Voltage High Alarm
threshold
Displays the interface index number used by SNMP to identify the interface.
Bias High Alarm
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power High
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
RX Power High
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp Low Alarm
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage Low Alarm
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias Low Alarm
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power Low
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
RX Power Low
Alarm threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp High Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage High
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias High Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power High
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
RX Power High
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temp Low Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Voltage Low
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Bias Low Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
TX Power Low
Warning threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Power Low Warning
threshold
Factory-dened setting. Value can dier between SFP and SFP+.
Temperature Current temperature of the SFPs. If this temperature crosses Temp High alarm/warning
thresholds, the temperature high alarm/warning ag is set to true.
Interfaces 649