Users Guide
rate-interval
Congure the trac sampling interval on the selected interface.
Syntax
rate-interval seconds
Parameters
seconds Enter the number of seconds for which to collect trac data. The range is from 5 to 299
seconds.
NOTE: Because polling occurs every 15 seconds, the number of seconds
designated here rounds to the multiple of 15 seconds lower than the entered
value. For example, if 44 seconds is designated, it rounds to 30; 45 to 59
seconds rounds to 45.
Defaults 299 seconds
Command Modes INTERFACE
Command History
This guide is platform-specic. For command information about other platforms, see the relevant Dell Networking
OS Command Line Reference Guide.
Version Description
9.10(0.0) Introduced on the S6100–ON.
9.8(1.0) Introduced on the Z9100–ON.
9.8(0.0P5) Introduced on the S4048-ON.
9.8(0.0P2) Introduced on the S3048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.2(1.0) Introduced on the Z9500.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.1.1.0 Introduced on the E-Series.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
6.1.1.0 Introduced
Usage Information The output of the show interfaces command displays the congured rate interval, along with the collected
trac data.
Related Commands
• show interfaces — display information on physical and virtual interfaces.
630 Interfaces