Service Manual

Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced the support for bmp-boot on the S-Series and Z-Series switches.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
Usage Information To display these changes in the show bootvar command output, save the running conguration to the
startup conguration (using the copy command) and reload system.
The keyword bmp-boot is used only when the device boots up from BMP. In case of industrial standard
upgraded device, the Dell networking OS stores the image partition upgraded from the DHCP oer in bmp-
boot variable.
cd
Change to a dierent working directory.
Syntax
cd directory
Parameters
directory (OPTIONAL) Enter one of the following:
flash: (internal Flash) or any sub-directory
nfsmount://<mount-point>/filepath: NFS mounted path
NOTE: While switching to a remote NFS le system, it is mandatory to
specify the mount-point that indicates the working directory on the
NFS le system. You cannot enter the root directory of the remote NFS
le system.
usbflash: (internal Flash) or any sub-directory
Command Modes EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Added NFS mount support. Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
File Management