Service Manual
Jumbo Capable : yes
POE Capable : no
FIPS Mode : disabled
Boot Flash : Present
Boot Selector : 3.20.0.0
Memory Size : 3203911680 bytes
Temperature : 0C
Voltage : ok
Serial Number : NA
Part Number : <PART NUMB Rev R>
Vendor Id : NA
Date Code : NA
Country Code : NA
Piece Part ID : <SER:)0
PPID Revision : R>
Service Tag : N/A
Expr Svc Code : 0
Auto Reboot : disabled
Burned In MAC : 00:00:00:00:00:00
No Of MACs : 3
-- Power Supplies --
Unit Bay Status Type FanStatus FanSpeed(rpm)
---------------------------------------------------------------------------
1 1 up AC up 18528
1 2 absent absent 0
-- Fan Status --
Unit Bay TrayStatus Fan1 Speed Fan2 Speed
------------------------------------------------------------------------------------
1 1 up up 19275 up 19275
1 2 absent
1 3 up up 19275 up 18904
Speed in RPM
Related Commands
• show version – displays the Dell Networking OS version.
• show hardware stack-unit – displays the data plane and management plane input and output statistics of a particular
stack member.
show tech-support
Display a collection of data from other show commands, necessary for Dell Networking technical support to perform
troubleshooting.
Syntax
show tech-support [stack-unit unit-id | page]
Parameters
stack-unit (OPTIONAL) Enter the keywords stack-unit to view CPU memory usage for
the stack member designated by unit-id. The unit ID range is from 1to 6.
page (OPTIONAL) Enter the keyword page to view 24 lines of text at a time. Press the
SPACE BAR to view the next 24 lines. Press the ENTER key to view the next line
of text.
When using the pipe command ( | ), enter one of these keywords to lter
command output. For details about ltering commands, refer to CLI Basics.
save Enter the keyword save to save the command output.
Control and Monitoring