Service Manual

Version Description
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
7.6.1.0 Introduced on the S-Series.
7.5.1.0 Introduced on the C-Series.
E-Series legacy
command
snmp-server enable traps
Enable SNMP traps.
Syntax
snmp-server enable traps [notification-type] [notification-option]
To disable traps, use the no snmp-server enable traps [notification-type]
[notification-option] command.
Parameters
notication-type Enter the type of notication from the following list:
bgpNotication of changes in the BGP process.
configNotication of changes to the startup or running conguration.
ecfmNotication of changes to ECFM.
ecmp — Enable an ECMP trap to notify of ECMP or link bundle trac
imbalances.
envmon — For Dell Networking device notications when an environmental
threshold is exceeded.
isisNotication of intermediate service traps.
lacpNotication of changes.
snmpNotication of RFC 1157 traps.
stpNotication of a state change in the spanning tree protocol (RFC
1493).
vltNotication of virtual link trunking.
vrrpNotication of a state change in a VRRP group.
xstpNotication of a state change in MSTP (802.1s), RSTP (802.1w), and
PVST+.
notication-option For the envmon notication-type, enter one of the following optional parameters:
cam-utilization
fan
supply
temperature
For the snmp notication-type, enter one of the following optional parameters:
authentication
coldstart
1364
Simple Network Management Protocol (SNMP) and Syslog