Service Manual

For a Loopback interface, enter the keyword loopback then a number from 0
to 16383.
For the Management interface on the stack-unit, enter the keyword
ManagementEthernet then the slot/port information. The slot range is from
1 to 11. The port range is 1.
For a port channel interface, enter the keywords port-channel then a
number. The range is from 1 to 128.
For a 100/1000 Ethernet interface, enter the keyword GigabitEthernet
then the slot/port information.
Command Modes
EXEC
EXEC Privilege
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series ExaScale.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
6.2.1.1 Introduced on the E-Series.
Usage Information
The dropEvent counter (sFlow samples dropped due to sub-sampling) shown in the following example
always displays a value of zero.
Example
Dell#show sflow
sFlow services are enabled
Egress Management Interface sFlow services are disabled
Global default sampling rate: 32768
Global default counter polling interval: 20
Global default extended maximum header size: 128 bytes
Global extended information enabled: none
1 collectors configured
Collector IP addr: 100.1.1.1, Agent IP addr: 1.1.1.2, UDP port: 6343 VRF:
Default
0 UDP packets exported
0 UDP packets dropped
0 sFlow samples collected
stack-unit 1 Port set 1
Gi 1/1: configured rate 16384, actual rate 16384 <<< sampling rate
sFlow