Service Manual
Usage Information The polling interval for an interface is the maximum number of seconds between successive samples of
counters sent to the collector. This command changes the global default counter polling (20 seconds)
interval. You can congure an interface to use a dierent polling interval.
Related Commands sow polling-interval (Interface) — sets the polling interval for an interface.
sow polling-interval (Interface)
Set the sFlow polling interval at an interface (overrides the global-level setting.)
Syntax
sflow polling-interval interval value
To return to the default, use the no sflow polling-interval interval command.
Parameters
interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The
default is the global counter polling interval.
Defaults The same value as the current global default counter polling interval.
Command Modes INTERFACE
Command History
This guide is platform-specic. For command information about other platforms, refer to the relevant Dell
Networking OS Command Line Reference Guide.
The following is a list of the Dell Networking OS version history for this command.
Version Description
9.8(0.0) Introduced on the S3048-ON and S4048-ON.
9.7(0.0) Introduced on the S6000-ON.
9.0.2.0 Introduced on the S6000.
8.3.19.0 Introduced on the S4820T.
8.3.11.1 Introduced on the Z9000.
8.3.7.0 Introduced on the S4810.
8.2.1.0 Introduced on S-Series Stacking.
8.1.1.0 Introduced on the E-Series ExaScale.
7.7.1.0 Introduced on the S-Series.
7.6.1.0 Introduced on the C-Series.
7.4.1.0 Introduced on the E-Series.
Usage Information This command sets the counter polling interval for an interface.
Related Commands sow polling-interval (Global) — globally sets the polling interval.
1352