Service Manual
• continuous: transmit echo request continuously
datagram size Enter the ICMP datagram size. The range is from 36 to 15360 bytes. The default is
100.
timeout Enter the interval to wait for an echo reply before timing out. The range is from 0
to 3600 seconds. The default is 2 seconds.
source Enter the IPv4 or IPv6 source ip address or the source interface. For IPv6
addresses, you may enter global addresses only. Enter the IP address in A.B.C.D
format.
• For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet
then the slot/port information.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
• For a port channel interface, enter the keywords port-channel then a
number. The range is from 1 to 128.
• For a VLAN interface, enter the keyword vlan then a number from 1 to 4094.
• For a Tunnel interface, enter the keyword tunnel then a number from 1 to
16383.
tos (IPv4 only) Enter the type of service required. The range is from 0 to 255. The
default is 0.
df-bit (IPv4 only) Enter Y or N for the “don't fragment” bit in IPv4 header.
• N: Do not set the “don't fragment” bit.
• Y: Do set “don't fragment” bit
Default is No.
validate-reply (IPv4 only) Enter Y or N for reply validation.
• N: Do not validate reply data.
• Y: Do validate reply data.
Default is No.
outgoing-interface (IPv6 link-local address) Enter the outgoing interface for ping packets to a
destination link-local address.
pattern pattern (IPv4 only) Enter the IPv4 data pattern. Range: 0-FFFF. Default: 0xABCD.
sweep-min-size Enter the minimum size of datagram in sweep range. The range is from 52 to 15359
bytes.
sweep-max-size Enter the maximum size of datagram in sweep range. The range is from 53 to
15359 bytes.
sweep-interval Enter the incremental value for sweep size. The range is from 1 to 15308 seconds.
interface (IPv4 only) Enter the outgoing interface for multicast packets. Enter the IP address
in A.B.C.D format.
• For a 1-Gigabit Ethernet interface, enter the keyword GigabitEthernet
then the slot/port information.
• For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet then the slot/port information.
114