Install Guide
Table Of Contents
- Dell EMC PowerSwitch N3200-ON Series Installation Guide
- Contents
- About this guide
- N3200-ON Series switch
- Site preparations
- N3200-ON Series switch installation
- Unpack
- Rack or cabinet hardware installation
- Ground cable
- Desktop
- N3208PX-ON ceiling-mount switch installation
- N3208PX-ON wall-mount switch installation
- Standard bracket two-post installation
- Two-post five-inch-offset switch installation
- Two-post flush-mount switch installation
- Wall- or ceiling-mount switch installation
- One RU ReadyRails installation
- Optics installation
- Switch start-up
- After switch placement
- Switch replacement
- External power adapter
- Power adapter holder assembly
- Wall or ceiling installation
- DIN rail installation
- Single-EPA and switch four-post installation
- Single-EPA and switch two-post center-mount installation
- Single-EPA and switch two-post front-mount installation
- Dual-EPAs two-post front-mount installation
- Dual-EPAs two-post center-mount installation
- Power supply
- Fans
- Management ports
- Installation using ONIE
- Specifications
- Dell EMC support
Components
The following power supply options are available for the N3200-ON Series switch:
● AC or DC power supply with integrated fan
● AC or DC power supply with integrated reverse-flow fan
NOTE: Reserve airflow is only supported on the N3224T-ON, N3248TE-ON, and N3248X-ON switches.
For the N3200-ON Series switches, power supply 1 (PSU1) and power supply 2 (PSU2) are on the right side of the switch. PSU1
is near the center of the switch; PSU2 is on the right edge of the switch.
N3224F-ON, N3224P-ON, N3224T-ON, N3248TE-ON, and N3248X-ON PSUs
1. Default PSU and ordered-separately PSU. PSU1 is near the center of the switch; PSU2 is on the right edge of the switch.
N3224PX-ON, N3248P-ON, and N3248PXE-ON PSUs
1. Default PSU and ordered-separately PSU. PSU1 is near the center of the switch; PSU2 is on the right edge of the switch.
The PSU has an integrated fan, which you cannot replace individually; if the fan integrated in a PSU fails, you must replace the
entire PSU.
WARNING:
Prevent exposure and contact with hazardous voltages. Do not attempt to operate this switch with
the safety cover uninstalled.
CAUTION: Remove the power cable from the PSU before uninstalling the PSU. Also, do not connect the power
cable before you insert the PSU in the switch.
NOTE: To comply with the GR-1089 Lightning Criteria for Equipment Interfacing with AC or DC Power Ports, use an
external surge protection device (SPD) at the AC or DC input of the router.
AC power cable clips
NOTE: These AC power cable clips apply to the compact N3208PX-ON switch only.
After you connect the AC power cable to the N3208PX-ON switch, attach the metal wire clip to the switch over each AC power
cable.
Power supply