White Papers

61 Using MLAG in Dell Networking N-Series Switches | version 1.5
MLAG peer 1 (N3024-2)
MLAG peer 2 (N3024-3)
show vpc brief
VPC domain ID...................................... 1
VPC admin status............................... Enabled
Keep-alive admin status................... Enabled
VPC operational status..................... Enabled
Self role................................................ Primary
Peer role.............................................. Secondary
Peer detection admin status........... Disabled
Operational VPC MAC......................
ECF4.BBF6.2512
Operational VPC system priority…. 32767
peer link details
-----------------
Interface.................................................. Po1
peer link admin status......................... Enabled
peer link STP admin status................. Enabled
Configured VLANs................................ 1,30
Egress tagged VLANs............................ 30
VPC Details
-----------
Number of VPCs configured...................... 2
Number of VPCs operational..................... 2
VPC id# 40
-----------
Interface................................................ Po40
Configured VLANs............................... 1,30
VPC interface state............................. Active
Local Members Status
----------------- ------
Gi1/0/1 Up
Gi1/0/2 Up
Peer Members Status
---------------- ------
Gi1/0/1 Up
Gi1/0/2 Up
VPC id# 50
-----------
Interface................................................ Po50
Configured VLANs............................... 1,30
VPC interface state............................. Active
Local Members Status
----------------- ------
Gi1/0/14 Up
Peer Members Status
---------------- ------
Gi1/0/13 Up
show vpc brief
VPC domain ID...................................... 1
VPC admin status............................... Enabled
Keep-alive admin status................... Enabled
VPC operational status..................... Enabled
Self role................................................ Secondary
Peer role.............................................. Primary
Peer detection admin status........... Disabled
Operational VPC MAC...................... ECF4.BBF6.2512
Operational VPC system priority…. 32767
peer link details
-----------------
Interface.................................................. Po1
peer link admin status......................... Enabled
peer link STP admin status................. Enabled
Configured VLANs................................. 1,30
Egress tagged VLANs............................ 30
VPC Details
-----------
Number of VPCs configured...................... 2
Number of VPCs operational..................... 2
VPC id# 40
-----------
Interface................................................ Po40
Configured VLANs............................... 1,30
VPC interface state............................. Active
Local Members Status
----------------- ------
Gi1/0/1 Up
Gi1/0/2 Up
Peer Members Status
---------------- ------
Gi1/0/1 Up
Gi1/0/2 Up
VPC id# 50
-----------
Interface................................................ Po50
Configured VLANs............................... 1,30
VPC interface state............................. Active
Local Members Status
----------------- ------
Gi1/0/13 Up
Peer Members Status
---------------- ------
Gi1/0/14 Up
show vpc brief command output for both N3024 MLAG peers in Two-tier topology